Our Short List of 3
- Best for: replacing a failed pump in an existing setup, or building a custom fueling point around a hose reel or remote dispenser.
- Flow rate: 35 GPM
- Power: 115V/230V AC
- Configuration: pump only, no hose, nozzle or meter included
- Pump type: rotary vane
- Best for: a new above-ground tank that needs a complete, metered fueling point in one purchase, logged in gallons.
- Flow rate: 35 GPM
- Power: 115V/230V AC
- Configuration: pump with mechanical meter package, gallons register
- Included in package: discharge hose and automatic nozzle
- Best for: fleet yards that reconcile fuel against vehicles and want dispensing data sent to a management system automatically.
- Flow rate: 35 GPM
- Power: 115V/230V AC
- Configuration: pump with digital meter package, pulser included
- Meter: 900CDP digital meter with integrated pulse output
All 4 Picks at a Glance
| Product | Specs | Action |
|---|---|---|
| Check price on Amazon | |
| Check price on Amazon | |
| Check price on Amazon | |
| Check price on Amazon |
🛒 Best Price Today on Amazon
Prime members get fast, free shipping on everything above, plus member-only deals. New members get a 30-day free trial — cancel anytime.
Every pump in this class carries the same headline number, so the flow rate is not the decision. The real decision is configuration: whether you need a bare pump that drops into a fueling setup you already own, a complete package with hose, nozzle and meter in one box, or a meter that reports every gallon to a fleet system. Wiring matters just as much, because these are fixed AC pumps for stationary tanks, and the wrong voltage setup or an undersized circuit will stop a 35 GPM pump faster than any flow limit.
This guide is for fleet yards, farms, construction operations and generator sites that fuel several machines a day from an above-ground tank. The four picks below all come from the Fill-Rite FR300 series and were chosen from their Amazon listings by configuration, meter type and included hardware, so you can match the package to the way your site actually records and dispenses fuel.
Quick Picks
As an Amazon Associate we earn from qualifying purchases
| Product | Best for | Key spec from title |
|---|---|---|
| Fill-Rite FR310VN | Building your own fueling setup around an existing hose and meter | 35 GPM, 115V/230V, pump only |
| Fill-Rite FR311VB | Fleets that track fuel in gallons with a simple mechanical register | 35 GPM with mechanical meter package |
| Fill-Rite FR319VBP | Yards that feed fuel data into a management system | 35 GPM with digital meter and pulse output |
| Fill-Rite FR311VLB | Operations that buy and record fuel in liters | 35 GPM with mechanical liter meter |
How to Choose
Pump only or a complete package
A pump-only model looks cheaper on the listing and can be the right buy, but only if your site already owns the rest of the fueling chain: suction pipe, discharge hose, nozzle and a meter if you track usage. Price the whole setup before deciding, because those parts add up quickly at this flow class, and a 1-inch hose rated for fuel is not a minor extra. A package that bundles the hose, automatic nozzle and meter in one box removes the compatibility guessing and usually lands on the tank as a single install job.
Metering: none, mechanical or digital with a pulse output
Fuel that is not measured tends to disappear quietly, so the meter choice is really an accountability choice. A mechanical register is simple, needs no batteries and survives dusty yards, but someone still has to read it and write the number down. A digital meter is easier to read at a glance, and the pulser version can send each dispensing event to a fuel management system, which is what turns a pump into a controlled fuel point. If drivers fuel themselves unsupervised, that reporting is worth more than any other feature here.
Power supply, wiring and duty cycle
These pumps run on 115V/230V AC and are built for fixed installations, not for clamping onto a truck battery at a job site. Confirm which voltage your tank location can supply, have the circuit sized for the motor, and remember that the series carries a 30-minute duty cycle: it is designed for repeated vehicle fills across the day, not for running flat-out for hours emptying one tank into another. If the pump will run from a generator during outages, check the motor’s nameplate amps and allow headroom for starting surge.
Rated flow versus flow at the nozzle
The 35 GPM figure is an open-flow rating, measured without the restriction of a full hose run and nozzle. Fill-Rite’s own data for this series puts flow in the supplied configuration closer to 27 GPM, and long hoses, filters and suction lift pull it down further. That is still fast enough to fill most equipment tanks in a few minutes, but it means hose diameter and suction setup matter: keep the suction side short, use the 1-1/4 inch inlet the pump expects, and do not choke a 35 GPM pump with an undersized hose.
The 4 Best Options
Fill-Rite FR310VN 115V/230V 35 GPM Fuel Transfer Pump (Pump Only)
- Best for: replacing a failed pump in an existing setup, or building a custom fueling point around a hose reel or remote dispenser.
- Flow rate: 35 GPM
- Power: 115V/230V AC
- Configuration: pump only, no hose, nozzle or meter included
- Pump type: rotary vane
replacing a failed pump in an existing setup, or building a custom fueling point around a hose reel or remote dispenser.
the suction tube, discharge hose, nozzle and any meter are separate purchases, so the finished setup costs more than the pump’s listing suggests.
The FR310VN is the starting point for anyone building or rebuilding a fueling point piece by piece. Because it ships as the pump alone, it suits sites that already run a hose reel, a remote dispenser or a meter they trust, and it is also the natural replacement when an existing FR300-series installation loses its pump but keeps its plumbing. The cast-iron rotary vane design is shared with the metered versions, so you are not trading durability for the lower parts count. Just budget honestly for everything that is not in the box before comparing it with the packages below.
Fill-Rite FR311VB 115V/230V 35 GPM Fuel Transfer Pump with Mechanical Meter Package
- Best for: a new above-ground tank that needs a complete, metered fueling point in one purchase, logged in gallons.
- Flow rate: 35 GPM
- Power: 115V/230V AC
- Configuration: pump with mechanical meter package, gallons register
- Included in package: discharge hose and automatic nozzle
a new above-ground tank that needs a complete, metered fueling point in one purchase, logged in gallons.
the mechanical meter cannot send data anywhere, so usage records still depend on someone reading the register and writing numbers down.
The FR311VB is the one-box answer for a new tank installation that needs to start fueling the day it arrives. The package adds a discharge hose, an automatic nozzle and a mechanical meter that registers in gallons, which covers the way most US farms and small fleets already keep their fuel logs. The mechanical register needs no power or batteries and can be read in bright sun or with gloves on, which suits outdoor tank pads. For a site setting up its first controlled fuel point, this is the configuration that asks the fewest follow-up questions.
Fill-Rite FR319VBP 115V/230V 35 GPM Fuel Transfer Pump with Digital Meter Package
- Best for: fleet yards that reconcile fuel against vehicles and want dispensing data sent to a management system automatically.
- Flow rate: 35 GPM
- Power: 115V/230V AC
- Configuration: pump with digital meter package, pulser included
- Meter: 900CDP digital meter with integrated pulse output
fleet yards that reconcile fuel against vehicles and want dispensing data sent to a management system automatically.
the pulser only earns its keep if you actually connect a fuel management system; without one, you are paying for reporting you never read.
The FR319VBP is built for yards where fuel is a controlled cost, not a shared convenience. Its 900CDP digital meter includes an integrated pulse output, so dispensing data can flow into a fuel management system instead of living on a clipboard. The package also carries an 18-foot hose and an ultra high-flow automatic nozzle with a truck stop spout, sized for the big filler necks on trucks and heavy equipment. If several drivers fuel at different hours and the office reconciles every gallon against vehicles, this is the version designed for that workflow.
Fill-Rite FR311VLB 115V/230V 35 GPM Fuel Transfer Pump with Mechanical Liter Meter
- Best for: operations that purchase, bill or report fuel in liters and want a simple mechanical register that matches.
- Flow rate: 35 GPM
- Power: 115V/230V AC
- Configuration: pump with discharge hose, automatic nozzle and mechanical liter meter
- Meter register: liters
operations that purchase, bill or report fuel in liters and want a simple mechanical register that matches.
the listing leads with diesel, so confirm gasoline approval on the product page if your tank holds gasoline, and do not order it for a gallons-based log.
The FR311VLB is the same mechanical meter package as the FR311VB, with one deliberate difference: the register counts in liters. That makes it the right pick for operations that buy fuel by the liter, run mixed fleets across the US-Canada border, or keep records for companies that report in metric. Everyone else should treat it as a caution, because a liter register on a gallons-based fuel log creates conversion errors that compound quietly all year. Check the register unit on the listing carefully before ordering, since the two packages look identical in photos.
Which One Fits Your Situation
You are setting up a brand-new tank and own no fueling hardware
Start with the FR311VB. The pump, hose, automatic nozzle and gallon meter arrive as one package, so the install is a single job and the site can fuel and log from day one. Buying the pump-only model first and chasing the remaining parts separately usually costs more time than it saves.
Your pump died but the hose, meter and nozzle are still good
Take the FR310VN. When the plumbing, meter and dispensing hardware on a site are already proven, replacing just the pump restores the setup at the lowest parts cost, and the shared FR300 mounting pattern keeps the swap straightforward. Inspect the old suction pipe and strainer while the pump is off.
Several drivers fuel unsupervised and the office tracks every gallon
Choose the FR319VBP. Its digital meter with pulse output feeds dispensing data to a fuel management system, which is the only setup here that can tie fuel to vehicles without relying on handwritten logs. That accountability is the feature that pays for itself in a multi-driver yard, especially once fuel costs are reviewed monthly.
Your fuel records, invoices or company reporting run in liters
Pick the FR311VLB and nothing else in this list. A mechanical register that counts in the same unit your invoices use removes a conversion step from every single fill, which is where small, persistent accounting errors usually creep in over a year of fueling across dozens of tanks and hundreds of fills.
Common Mistakes
- Expecting a true 35 GPM at the nozzle; that figure is open flow, and a real installation with hose, filter and meter delivers noticeably less.
- Ordering the pump-only model and forgetting the suction pipe, hose, nozzle, bonding and grounding hardware it needs before it can move a drop of fuel.
- Pumping gasoline through a configuration whose listing only covers diesel and light fuels, instead of checking the fuel compatibility line on the product page.
- Treating the pump as continuous-duty and running it for hours at a time, when the series is built around a 30-minute duty cycle with cool-down periods.
- Skipping the meter to save money, then having no record when fuel shrinkage shows up at the end of the quarter.
Frequently Asked Questions
How long does a 35 GPM pump take to fill a 100-gallon tank?
On paper, 100 gallons at 35 GPM is under three minutes, but that rating is open flow. Through a real hose, filter and nozzle, this series delivers closer to the high twenties per minute, so expect roughly four minutes for 100 gallons in a typical installation, plus the time spent connecting and disconnecting.
Can a 35 GPM AC fuel pump run from a generator?
Yes, and that is a common setup at generator sites and remote yards. The pump is an AC motor load, so size the generator for the motor’s nameplate running amps and leave headroom for the starting surge. A generator that runs the pump easily once started can still trip if it is asked to start the motor alongside other loads.
Is a 35 GPM pump a good choice for a pickup truck transfer tank?
Not really. These are 115V/230V fixed-installation pumps meant to live on a stationary tank with mains power. Truck-bed transfer tanks normally use 12V DC pumps in the 15 to 25 GPM range that run from the vehicle battery. A 35 GPM AC pump belongs on the yard tank that fills the trucks, not in the truck bed.
What is the difference between the FR311VB and the FR319VBP?
Both are complete packages on the same 35 GPM pump, but the metering differs. The FR311VB uses a mechanical meter that registers in gallons and is read by eye. The FR319VBP uses a digital meter with an integrated pulse output, so it can report dispensing data to a fuel management system, and it ships with an ultra high-flow nozzle.




Write Your Review