Central air conditioning is usually the single largest electrical load in a home, and it is the appliance that decides whether a generator or battery system can keep you comfortable in a summer outage. Its wattage depends on tonnage, efficiency rating (SEER or SEER2), compressor type and outdoor temperature. This guide covers typical running watts, the starting surge that trips generators, how to read your outdoor unit’s label, and what a day of cooling costs in kilowatt-hours.
Tonnage and BTU basics
One ton of cooling equals 12,000 BTU per hour. Residential systems typically range from 1.5 to 5 tons. A rough guide is one ton per 500–700 square feet of living space, though insulation, windows and climate change that figure considerably.
Typical central AC wattage
| System size | BTU/hr | Running watts (SEER 14–16) | Starting watts (fixed-speed) |
|---|---|---|---|
| 1.5 ton | 18,000 | 1,300–1,800W | 4,500–7,000W |
| 2 ton | 24,000 | 1,700–2,300W | 6,000–9,000W |
| 2.5 ton | 30,000 | 2,100–2,800W | 7,500–11,000W |
| 3 ton | 36,000 | 2,500–3,500W | 9,000–13,000W |
| 4 ton | 48,000 | 3,300–4,500W | 12,000–16,000W |
| 5 ton | 60,000 | 4,200–5,500W | 14,000–20,000W |
Running watts include the outdoor compressor and condenser fan. The indoor air handler or furnace blower adds another 300–800W for PSC motors, or 100–500W for ECM variable-speed blowers.
Reading the outdoor unit label
The data plate on the condenser lists RLA (rated load amps) and LRA (locked rotor amps) for the compressor, plus fan motor amps. Multiply RLA by 240V to estimate compressor running watts, and LRA by 240V for the instantaneous start surge. For example, a 3-ton unit with 14 RLA and 73 LRA draws roughly 3,360W running and can spike near 17,500W for a fraction of a second. Real starting demand is usually somewhat lower than the LRA figure, but it shows why central air is so hard on generators.
MCA and MOCP
The label also lists Minimum Circuit Ampacity and Maximum Overcurrent Protection. These are wiring figures, not consumption figures; do not use them to estimate watts.
Efficiency ratings and consumption
SEER measures seasonal cooling output per watt-hour. A higher SEER means less energy for the same cooling. Moving from an older 10 SEER system to a 16 SEER unit cuts energy use by roughly 35–40%.
| 3-ton system | Approx. running watts | kWh for 8 hours at 70% duty |
|---|---|---|
| SEER 10 (older) | ~4,000W | ~22 kWh |
| SEER 14 | ~3,000W | ~17 kWh |
| SEER 18+ variable speed | ~2,000W avg (modulating) | ~11 kWh |
Variable-speed and inverter systems
Modern inverter-driven heat pumps and variable-speed AC systems ramp their compressor up gradually, eliminating most of the start surge. They also run at partial capacity most of the time, drawing as little as 30–40% of peak. That makes them dramatically easier to back up with a generator or large battery system.
Factors that raise consumption
- Outdoor temperatures above 95°F reduce efficiency and increase draw by 10–20%.
- Dirty condenser coils and clogged filters raise head pressure and power use.
- Low refrigerant charge makes compressors run longer.
- Leaky ductwork in hot attics wastes 20–30% of cooling.
Measuring your own system
A clamp meter on one leg of the condenser’s supply while running gives amperage; multiply by 240V. Smart panels and whole-home energy monitors provide real-time wattage and daily kWh, which are the most accurate numbers for sizing backup power. Measure on a hot afternoon to capture worst-case draw.
Reducing load during outages
Raising the thermostat from 72°F to 78°F can reduce cooling energy by roughly 20–30%. Closing blinds on sun-facing windows, running ceiling fans (30–75W each) and cooling only occupied floors reduce compressor runtime further.
Heat pumps in cooling mode
A heat pump cooling your home behaves like a central AC of the same tonnage and efficiency, so the same running-watt ranges apply. The difference appears in winter: in heating mode, a heat pump draws similar compressor power, but if outdoor temperatures drop below its balance point, electric auxiliary heat strips kick in. Those strips commonly draw 5,000–15,000W, which is far beyond what most generators can support. If you rely on a heat pump, plan to lock out auxiliary heat while on backup power and accept a slightly cooler house. For summer cooling, the numbers in this guide hold, and a variable-speed heat pump is one of the most generator-friendly cooling systems you can own.
FAQ
How many watts does a 3-ton AC use?
Typically 2,500–3,500W while running, with a start surge that can reach 9,000–13,000W on fixed-speed compressors.
Does a soft starter reduce central AC wattage?
It does not change running watts, but it reduces the start surge by roughly 50–70%, which allows a much smaller generator to start the compressor.
Bottom line
Central air uses about 1,300–5,500W running depending on size and efficiency, with starting surges three to five times higher on fixed-speed units. Read the RLA and LRA on your condenser, consider a soft starter, and use real kWh measurements when sizing backup power.